Vacuum Pressure Impregnated - Kiln Dried After Treatment (KDAT) Lumber, Plywood, Timber, Shake Shingles, Architectural Millwork, Specialty Treatments
ASTM E84 CLASS "A"; UL 723 TYPE 1; NFPA 255; UBC 42-1
  (Intertek) ASTM E84 -30min LUMBER exterior/interior
  (Intertek) ASTM E84 -30min PLYWOODexterior/interior
  (SWRI) UL 1256 (ASTM E84) LUMBER exterior/interior
  (SWRI) UL1256(ASTM E84)PLYWOOD exterior/interior
  (Intertek) ASTM E2768 (ASTM E84) OSB
  (Intertek) ASTM E2768 (ASTM E84) I-JOISTS
  (Maxim)ASTM E-84 Standard or D-3806 equivalency
  (Maxim)ASTM E-84 Standard or D-3806 equivalency
  (Maxim)ASTM E-84 Standard or D-3806 equivalency
  (Maxim)ASTM E-84 Standard or D-3806 equivalency
  (Universal Lab) ASTM E 84;UL723; NFPA255; UBC 42-1
Flame Spread <25 ; smoke generation <100

Classified FRT Exterior Lumber
ASTM E84 Class A - UL 723
Kiln Dried After Treatment (KDAT)
Flame Spread 0
Smoke Developed 120
KDAT 19
No increase in the Listed Classification
When subjected to the Standard Rain
test ASTM D2898

Classified FRT Exterior Plywood
ASTM E84 Class A - UL 723
Kiln Dried After Treatment (KDAT)
Flame Spread 0
Smoke Developed 75
KDAT 15
No increase in the Listed Classification
When subjected to the Standard Rain
test ASTM D2898

 

Flame Safe Fire Retardant Coatings

are compliance tested to meet the following fire safety and building code requirements:
ASTM E84 Class A, UL723 Type 1, NFPA 255, NFPA 703,UBC 42-1 for interior use and exterior use SWRI 1256 (ASTM E84) plywood; SWRI 1256 (ASTM E84) lumberd UL 723; UL 723 CANADA; SWRI ASTM E84
ASTM D2898 procedure exterior fire retardant plywood, exterior fire retardant lumber and timbers;
ASTM E108 for fire retardant coating wood, cedar and pine shake shingles Class B;


NFPA 701, FAR25.853 a &b (Federal Aviation Req.), Federal Standard 16CFR [FF4-72] (mattress ticking), Boston, NY- NJ Port Authority, Cal 1237.1, and the Cal Tech 117-F for fire retardant spray on coatings for fabrics and textiles;

NFPA701 - ASTM E84 for fire retardant thatch


International Maritime Organization Resolution A.753(18) & ASTM F1173-95 wet classification for plastic pipe; NFPA 701 for polyurethante styrofoam, styrofoam


ASTM E162 & 662, Federal standard PPP-B-320, PPP-B-636 and PPP-B-640L fire retardant coating for corrugated packaging, cardboard box and paper industry; and


CAL Administrative Code, Title 19 Public Safety, Art. 3,Sec. 1264.3 spray on fire retardant coating for Christmas trees.